RSS feed source: International Atomic Energy Association--Nuclear & Radiological Events

External contamination of a worker beyond the annual statutory limit to the skin

Print View Posted on: 05 August 2025

Event Date: 09 June 2025 Event Type: Power Reactor Event Location: France, CATTENOM-3 INES Rating: 2 (Final)

On 12 June 2025, the operator of the Cattenom nuclear power plant reported a significant radiation protection event concerning the exceeding of an annual individual dose limit by an EDF contractor.
On 9 June 2025, this contractor was installing lead matting in reactor building 3, which was shut down for partial inspection. During the check carried out at the exit of the controlled area, skin contamination was detected on the contractor’s cheek. The worker was immediately taken into care and the radioactive particle causing the contamination was removed.
The occupational physician assessed the dose received, taking into account the worker’s activities within the reactor building. This assessment showed that the dose received by the worker’s cheek exceeded the regulatory limit for the equivalent skin dose (500 mSv).
As soon as the contamination was discovered, the operator took action to identify its source. However, radiological checks carried out in the premises where the agent was present

Click this link to continue reading the article on the source website.

RSS feed source: International Atomic Energy Association--Nuclear & Radiological Events

External contamination of a worker beyond the annual statutory limit to the skin

Print View Posted on: 05 August 2025

Event Date: 24 July 2025 Event Type: Power Reactor Event Location: France, GRAVELINES-1 INES Rating: 2

On 25 July 2025, the operator of the Gravelines nuclear power plant reported a significant radiation protection event concerning the exceeding of an annual individual dose limit by an EDF contractor.
Reactor 1 at the Gravelines nuclear power plant was in shut down for maintenance and refuelling. During the night of 23 to 24 July, as part of radiographic testing of a pipe located in the reactor building, a worker was contaminated on the head. This contamination was detected at the exit of the reactor building during a radiological check.
The worker was taken care of by the changing room attendant in order to remove the radioactive particles, and then by the site’s medical service.
The occupational physician carried out a conservative assessment of the dose received, taking into account the worker’s activities within the reactor building. This assessment showed that the dose received by the worker’s neck exceeded the regulatory limit for equivalent skin dose (500

Click this link to continue reading the article on the source website.

RSS feed source: International Atomic Energy Association--Nuclear & Radiological Events

Localised irradiation of a worker’s arm by the beam of a particle accelerator

Print View Posted on: 01 August 2025

Event Date: 22 July 2025 Event Type: Radiation Source Event Location: France, National Centre for Research and Restoration C2RMF INES Rating: 3 (Final)

On 24 July 2025, the National Centre for Research and Restoration in French Museums (C2RMF) reported to the ASNR a significant radiation protection event related to the localised irradiation of a worker by the beam of the AGLAE particle accelerator, used for analysing works of art and ancient objects.
The radiation caused an erythema at the beam impact point on the worker’s arm, i.e. a first-degree radiation burn characterised by reddening of the skin, which is typical of a deterministic effect of ionising radiation.
The worker was taken into care by his general health doctor and the occupational health doctor, with support from a specialist doctor from the reference regional health centre for nuclear and radiological risk and ASNR experts for dose reconstruction.
The ASNR conducted an on-site inspection on 30 July 2025. This inspection examined the initial causes identified by the C2RMF, which include a malfunction of the

Click this link to continue reading the article on the source website.

RSS feed source: International Atomic Energy Association--Nuclear & Radiological Events

Workers Exceeded Annual Dose Limit

Print View Posted on: 17 July 2025

Event Date: 08 April 2025 Event Type: Irradiation/Accelerator Facility Event Location: United States of America, Noblesville, Indiana/ Curium US LLC INES Rating: 2 (Final)

On April 8, 2025, two workers were performing waste handling activities in a hot cell basement of a cyclotron facility that produces strontium-82 from metallic rubidium targets. One worker removed a high-level liquid waste container from a shielded barrel and placed the unshielded container on the ground adjacent to the work area, where activities continued for approximately 15 minutes. Both workers’ electronic dosimeters alarmed for high dose soon after the container was removed from shielding; however, neither worker noticed these alarms because of the personal protective equipment they had donned, including respirators. Radiation surveys were performed upon entry to the area and prior to removing the container from shielding, but not again until after the workers left the area and noticed the excessive doses recorded on their electronic dosimeters. Radiation dose rates on contact with the waste container exceeded 9.99 Sv/hr (999 R/hr), which was the upper limit of available instrumentation. The licensee later

Click this link to continue reading the article on the source website.