Accidential Exposure of Industrial Radiography Worker
Print View Posted on: 26 December 2024
Event Date: 20 April 2015 Event Type: Radiation Source Event Location: Korea, Republic of, Busan INES Rating: 2 (Final)
On April 20, 2015, two workers were conducting a industrial radiography for Non-Destructive Test on the welds of a large steel product. During the process, the guide tube of the irradiator was not properly connected, causing the radiation source (Co-60, 1.85 TBq) to be withdrawn but not retrieved. One of the workers entered the radiographic testing room to retrieve the radiation source but accidentally stepped on the source without realizing its location, resulting in radiation exposure. On May 6, 2015, erythema was observed on the sole of his right foot, leading to the recognition of excessive radiation exposure. The doses were assessed as an effective dose of 0.9 mSv and a foot equivalent dose of 2.5 Sv.
INES Rating: 2 – Incident (Final) as per 29 November 2015
Impact on people and the environment Release beyond authorized limits? No